The 220kV / 230kV Power Transformer is a high-voltage oil-immersed transformer designed for utility substations, transmission networks, large industrial facilities, renewable energy integration, and high-capacity power transmission projects. It provides reliable voltage transformation, efficient power transmission, and stable long-term operation under demanding grid conditions.

Key Features:

  • High-Voltage Insulation System
  • High Transmission Efficiency
  • Strong Short-Circuit Capability
  • Reliable Thermal Performance

The 220kV / 230kV Power Transformer is a high-voltage oil-immersed transformer engineered for utility substations, transmission networks, power plants, renewable energy projects, and large industrial power systems. It is designed to provide reliable voltage transformation, efficient power transmission, and stable long-term operation under demanding grid conditions.

The transformer features an optimized magnetic circuit, reinforced winding structure, high-performance insulation system, and reliable cooling configuration to ensure electrical, mechanical, and thermal stability during continuous operation. Depending on project requirements, it can be equipped with an On-Load Tap Changer (OLTC) for precise voltage regulation and flexible grid operation.

Each transformer can be customized according to the required rated capacity, voltage ratio, frequency, impedance voltage, vector group, tap range, insulation level, cooling method, neutral configuration, and applicable international standards.

For large-scale substation and EPC projects, Zisheng provides project-oriented transformer solutions covering technical design, manufacturing, factory testing, export preparation, and delivery. Optional monitoring and protection systems can also be integrated to support reliable operation and condition monitoring throughout the transformer’s service life.

The 220kV / 230kV Power Transformer is suitable for high-voltage substations, transmission and distribution networks, power generation facilities, solar and wind power plants, mining projects, and large industrial electrical systems where high reliability, efficiency, and long service life are essential.

About ZISHENG ELECTRICAL

Zisheng are a professional 19+ years manufacturer in producing Oil-Immersed Transformers, Compact Substation, Pad Mounted Transformers, Pole Mounted Transformers and Dry Type Transformers. We own the certificates of ISO/CE/IEC 60076 and TUV Rheinland.
Transformers undergo rigorous FAT and type testing, support voltage/capacity customization. Welcome to consult for Catalog and Product. you can contact us at email [email protected].

220kV Grid Substation Power Transformer Project

Project Overview

A customized 220kV Power Transformer was supplied for a high-voltage grid substation project, providing reliable voltage transformation between the transmission network and the downstream power system.

The project required a high-capacity transformer capable of stable continuous operation under demanding grid conditions, with reliable insulation performance, efficient cooling, flexible voltage regulation, and comprehensive protection.

Project Requirements

The project required the transformer to meet the following key requirements:

  • 220kV high-voltage transmission system
  • High-capacity three-phase transformer
  • Stable long-term outdoor operation
  • High short-circuit withstand capability
  • Reliable high-voltage insulation system
  • On-load voltage regulation
  • Efficient heat dissipation and cooling
  • Comprehensive transformer protection
  • Factory acceptance testing before shipment
  • Export-ready packing and transportation

Customized Technical Solution

Zisheng developed the transformer configuration according to the project’s electrical and environmental requirements.

The solution included:

220kV High-Voltage System
The high-voltage winding and insulation system were designed according to the specified voltage and insulation requirements of the substation.

On-Load Tap Changer
An OLTC system was configured to provide flexible voltage regulation and help maintain stable output voltage under varying grid conditions.

Optimized Cooling System
The cooling system was selected according to the transformer’s rated capacity and thermal requirements, with radiator and fan configurations customized for reliable continuous operation.

Reinforced Winding Structure
The winding and mechanical support system were designed to withstand electromagnetic forces generated during short-circuit conditions.

Comprehensive Protection
The transformer can be equipped with Buchholz relay, pressure relief device, oil and winding temperature indicators, oil level monitoring, and other protection components according to the project specification.

Optional Online Monitoring
For critical substations, online monitoring solutions such as dissolved gas analysis, bushing monitoring, and transformer condition monitoring can be integrated.

Manufacturing & Quality Control

Before shipment, the transformer underwent factory inspection and testing according to the agreed technical specification and applicable standards.

The testing program can include:

  • Winding resistance test
  • Voltage ratio and vector group test
  • No-load loss and current test
  • Load loss and impedance test
  • Applied voltage test
  • Induced voltage test
  • Insulation performance verification
  • Tap changer operation test
  • Oil leakage test
  • Additional type and special tests when required

Factory acceptance testing can also be arranged with customer representatives, EPC contractors, consultants, or third-party inspection agencies.

Delivery & Project Support

After successful factory testing, the transformer was prepared for international transportation with suitable export protection and project documentation.

The project supply can include:

  • Main transformer
  • OLTC system
  • Cooling equipment
  • High-voltage and low-voltage bushings
  • Protection devices
  • Transformer monitoring equipment
  • Technical drawings
  • Test reports
  • Operation and maintenance documentation
  • Export packing and shipping support

Project Value

The 220kV Power Transformer solution provides the substation with a reliable high-voltage transformation system designed for long-term grid operation.

Through customized engineering, controlled manufacturing, factory testing, and project-oriented delivery, Zisheng supports EPC contractors, utilities, power developers, and industrial customers with high-voltage transformer solutions for demanding power infrastructure projects.

Parameter Technical Specification
Product Type Three-Phase Oil-Immersed Power Transformer
Application Transmission Substation / Grid Substation / Power Plant / Industrial Project / Renewable Energy
Rated Voltage Class 220kV / 230kV
Rated Capacity Customized, typically according to project requirements
Phase Three Phase
Rated Frequency 50Hz / 60Hz
High Voltage 220kV / 230kV
Medium Voltage Customized
Low Voltage Customized
Voltage Ratio Customized according to grid requirements
Rated Current Calculated according to rated capacity and voltage
Connection Group Dyn11 / YNd11 / YNyn0 / Other customized
Neutral Point Neutral grounded / Customized
Tap Changer OLTC / Off-Circuit Tap Changer
Tap Range Customized, commonly ±8 × 1.25% or according to project requirements
Tap Positions Customized
Tap Changer Location HV / MV winding, according to design
Cooling Method ONAN / ONAF / OFAF / ODAF
Insulating Medium Mineral Transformer Oil / Approved Insulating Fluid
Core Material High-Quality Grain-Oriented Silicon Steel
Winding Conductor High-Quality Copper / Aluminum
Winding Type Disc / Helical / Layer Winding according to design
Insulation System Oil-Paper Insulation System
HV Insulation Level According to IEC / IEEE / GB requirements
Lightning Impulse Withstand According to specified insulation level
Power-Frequency Withstand According to applicable standard
Partial Discharge According to applicable project requirements
Impedance Voltage Customized according to system requirements
No-Load Loss Optimized according to rated capacity and efficiency requirements
Load Loss Optimized according to project specification
No-Load Current According to design and applicable standard
Temperature Rise According to applicable IEC / IEEE / GB requirements
Oil Temperature Rise According to specified design requirements
Winding Temperature Rise According to specified design requirements
Enclosure Outdoor Weather-Resistant Tank
Tank Structure Sealed / Conservator Type
Transformer Oil Tank Main Tank with Radiators
Conservator Optional / Project Specific
Cooling Radiator Detachable / Fixed, according to design
Bushing Porcelain / Composite / Condenser Bushing
Buchholz Relay Optional / According to transformer configuration
Pressure Relief Device Standard protection configuration
Oil Level Indicator Provided according to design
Oil Temperature Indicator Optional / Standard according to specification
Winding Temperature Indicator Optional / Standard according to specification
Online Monitoring Optional
DGA Monitoring Optional Online Dissolved Gas Analysis
Bushing Monitoring Optional
OLTC Monitoring Optional
Installation Outdoor / Indoor according to project
Altitude Customized according to installation site
Ambient Temperature According to installation environment
Applicable Standard IEC / IEEE / GB / Customer Specification
Factory Testing Routine Tests / Type Tests / Special Tests as Required
FAT Available according to EPC / Utility Inspection Plan
Service Life Designed for long-term grid operation

Typical Voltage Configurations

The transformer can be engineered for different high-voltage grid configurations, including:

  • 220 / 110kV
  • 220 / 66kV
  • 220 / 33kV
  • 220 / 20kV
  • 220 / 13.8kV
  • 230 / 115kV
  • 230 / 69kV
  • 230 / 34.5kV
  • 230 / 13.8kV
  • Other project-specific voltage ratios

Recommended Project Specification

For an EPC or utility quotation, the customer should ideally provide:

Rated Capacity + HV Voltage + MV/LV Voltage + Frequency + Vector Group + Impedance + Tap Range + Cooling Method + Insulation Level + Applicable Standard + Installation Conditions

This allows the transformer to be engineered according to the actual grid code, substation design and project technical specification, rather than using a generic standard configuration.

The 220kV / 230kV Power Transformer is designed for high-voltage transmission, grid interconnection, and large-scale power infrastructure projects. Its customized electrical configuration and high-voltage insulation system make it suitable for demanding utility and industrial applications.

1. Utility Substations

Used in 220kV and 230kV transmission substations for voltage transformation between high-voltage transmission networks and regional distribution systems.

Typical applications include:

  • Grid substations
  • Transmission substations
  • Regional power networks
  • Grid expansion and reinforcement projects
  • Substation upgrading projects

2. Power Transmission Networks

The transformer provides reliable voltage transformation for high-capacity transmission systems, supporting efficient and stable power delivery over long distances.

It can be configured according to:

  • Transmission voltage
  • Grid frequency
  • System capacity
  • Short-circuit requirements
  • Voltage regulation requirements
  • Local grid standards

3. Power Plants

Suitable for large power generation facilities requiring high-voltage grid connection and voltage transformation.

Applications include:

  • Thermal power plants
  • Hydroelectric power plants
  • Gas-fired power plants
  • Combined-cycle power plants
  • Other large-scale generation facilities

4. Solar Power Plants

The transformer can be integrated into large-scale photovoltaic power projects to provide high-voltage transformation between the renewable energy collection system and the transmission grid.

It is suitable for:

  • Utility-scale solar farms
  • Solar power generation substations
  • PV grid-connection projects
  • Renewable energy transmission systems

5. Wind Power Projects

Designed for high-voltage grid connection of large wind power projects, including onshore and other large-scale renewable energy installations.

The transformer can be customized according to the project’s:

  • Grid connection voltage
  • Rated capacity
  • Voltage regulation requirements
  • Cooling conditions
  • Environmental conditions

6. Large Industrial Facilities

220kV / 230kV power transformers can be used in large industrial facilities with high electrical demand and dedicated high-voltage substations.

Typical industries include:

  • Mining
  • Metallurgy
  • Steel production
  • Petrochemical
  • Cement
  • Manufacturing
  • Large infrastructure facilities

7. Mining Projects

High-capacity transformers are suitable for mining operations where reliable electrical supply is required for heavy machinery, processing plants, pumping systems, and auxiliary facilities.

Customized designs can accommodate demanding environmental conditions such as high altitude, dust, temperature variations, and remote project locations.

8. Industrial & Infrastructure EPC Projects

The transformer is suitable for EPC contractors, electrical contractors, project developers, consultants, and utility companies requiring customized high-voltage transformer solutions.

Project support can cover:

Technical Design → Manufacturing → Factory Testing → Inspection → Export Packing → Transportation → Site Delivery

9. Grid Interconnection Projects

The 220kV / 230kV transformer can be used for connecting new power generation facilities, industrial loads, and regional electrical networks to existing high-voltage transmission systems.

It can support grid modernization, capacity expansion, renewable energy integration, and new substation construction.

10. Substation Expansion & Upgrading

Suitable for replacing aging transformers or increasing transformer capacity in existing substations.

Customized solutions can be developed according to existing:

  • Substation layout
  • Voltage levels
  • Transformer capacity
  • Protection system
  • Cable and busbar configuration
  • Space and transportation limitations

Typical Project Types

220kV / 230kV Power Transformers can be supplied for:

  • Transmission substations
  • Distribution substations
  • Power generation projects
  • Solar PV projects
  • Wind power projects
  • Mining projects
  • Industrial substations
  • Grid reinforcement projects
  • Grid interconnection projects
  • Substation expansion projects
  • Large EPC electrical projects

Project-Oriented Transformer Solutions

For large-scale projects, transformer specifications are developed according to the actual grid requirements, load profile, environmental conditions, installation site, applicable standards, and project technical specifications.

This makes the 220kV / 230kV Power Transformer suitable for complex utility, EPC, industrial, and renewable energy projects where reliability and customized engineering are essential.

A 220kV power transformer is a high-voltage transformer primarily used in transmission substations and large power systems to transform electrical voltage between transmission and distribution levels.

The main difference is the rated high-voltage level and the corresponding insulation, bushing, clearances, and system design requirements. The final configuration should match the local grid voltage and applicable standard.

Yes. An on-load tap changer (OLTC) can be configured when voltage regulation is required during transformer operation.

Yes. The HV/LV voltage ratio can be customized according to the customer’s grid connection and substation requirements.

Capacity is project-dependent. 220kV/230kV transformers are commonly designed for large transmission and substation applications, with the final MVA rating determined by the load and grid requirements.

Depending on the transformer capacity and thermal requirements, cooling configurations can include ONAN, ONAF, OFAF, and ODAF.

Yes. Optional monitoring systems can include temperature, oil level, dissolved gas, bushing, partial discharge, OLTC, and other condition-monitoring functions.

The transformer can be designed and tested according to applicable IEC, IEEE, GB, or other project-specific standards, subject to technical review.

Yes. The product can be configured for EPC contractors, utilities, substations, power plants, renewable energy projects, and large industrial power systems.

Yes. Factory acceptance testing and related documentation can be arranged according to the project inspection plan and contractual requirements.